      |  | Phillips Pump FPC series fill point controllers are
designed for use with a transport off-loading pump or for fuel drops with a
pumper truck to control the transfer of fuel to above ground storage tanks. With
enclosures suitable for outdoor use, or with explosion proof enclosures for
hazardous areas, our FPC controllers provides the circuitry for monitoring tank
levels and alarm sensing points. Bright LED alarm lights and a loud sounding
horn warn of alarm conditions with contact points provided for controlling
external devices such as solenoid valves, pumps or remote alarm stations. 
 While the controls are usable with a variety of field sensors, our series FPC
controller is optimized for high tank level control and assures complete
  safety and minimum installation cost by supplying only low current,
intrinsically safe wiring between controller and tank sensors. 
 With leak detection circuity that prevents the filling of leaking tanks, the
fill point controller warns the operator at the tank full 90% level. The system
allows the operator to continue filling and/or drain the fill hose up to the 95%
level at which time all filling operations are locked out and an alarm is
activated. Visual and audible level, leak alarms and indicating lights are also
provided.
 Features: 
  Lockable enclosure with controls tucked away to prevent tampering or unauthorized use
Tank full / tank high level, and leak detected visual alarms 
 Audible alarm buzzer 
 Power on indicator light 
System on, off and reset push-buttons 
Able to interface with existing third party tank gauging systems or optional bi-level float switch for tank full and tank high level warnings are available
 
Optional solenoids are available for installation in the fuel supply lines to control fuel flow for multi-tank set ups 			and to lock out filling operations at tank full and tank high alarm levels 
Our FPC-DR series includes a digital tank level readout with the alarms listed above. The DR series interfaces with optional continuous level transmitting probes or with existing third party tank gauging
 systems.
 |  
 
	| Part
      Number | Description |  
	| FPC-10 | Single tank fill point controller with tank full, tank high level and tank leak alarms |  
	| FPC-10-DR | Same as above with digital tank level indicator in percent volume |  
	| FPC-10X | Single tank fill point controller, explosion proof enclosure with tank full, tank high level and tank leak 		alarms |  
	|  |  |  
	| FPC-20 | Dual tank fill point controller with tank selector, tank full, tank high level and tank leak alarms |  
	| FPC-20-DR | Same as above with digital tank level indicator in percent volume |  
	| FPC-20X | Single tank fill point controller, explosion proof enclosure with tank selector, tank full, tank high level 		and tank leak alarms |  Note: Specify Voltage    120 VAC, 1 phase, 60 HZ	208 VAC, 3 phase, 60 HZ 208 VAC, 1 phase, 60 HZ	230 VAC, 3 phase, 60 HZ
 230 VAC, 1 phase, 60 HZ	460 VAC, 3 phase, 60 HZ
 Note: For Multi tank systems change part number. Example: FPC-30-1/120 is for a three tank,
115 VAC, single phase system.  Each multi-tank system requires an optional high level shut off, flow direction control
valve . 
	| Our Most Popular Options |  
	| Option | Description |  
	|  |  |  
	| 1250 | c-
      Three level float switch for tank high level, pump on & pump off with explosion proof junction box. (Note: 			to be used with PTC-10R or PTC-20RR series, specified tank size, 1” NPT tank top fitting required) |  
	|  | d
      - Four level float switch for tank high level, pump on, pump off & low level with explosion proof junction 			box. (Note: to be used with PTC-10S or PTC-20SS series, specified tank size, 1” NPT tank top fitting 			required) |  
	|  | e
      - Five level float switch for tank high-high and high level, pump on, pump off & low level with explosion 			proof junction box. (Note: typically used with PTC-20SR, PTC-30SSR series, specified tank size, 1” 			NPT tank top fitting required) |  
	|  |  |  
	| 1251 | Continuous reading level gauge, capacitance type with explosion proof junction box (Note: 				tank size must be specified, 3/4” NPT tank top fitting required, shipped loose with system) |    
PHILLIPS PUMP specializes in controlling, monitoring and transferring fuel........