PUMP/TANK LEVEL CONTROLLERS
|
Phillips Pump PTC series tank level controllers and alarm consoles are designed for use with any tank and sensing device that transmits an alarm condition by opening or closing switch contacts. While the controls are usable with a variety of field sensors, our series
PTC controller is optimized for level control and assures complete safety and minimum installation cost by requiring only low current, intrinsically safe wiring between console and tank switch.
Housed in a NEMA 1 enclosure, the circuitry provides for monitoring fuel level and alarm sensing points. Bright incandescent alarm lights and a loud sounding horn warn of alarm conditions. Dry contacts are provided for controlling external devices such as valves, or remote alarm stations.
Operation: Phillips PTC controller transmits a signal to a tank mounted level switch. When the switch senses a fuel requirement condition the switch transfers and the
PTC circuit energizes the pump circuit. If an alarm condition is sensed, the
PTC will energize the audible horn and appropriate warning indicator light. The light will remain on after silencing the horn by pressing the reset button. At any time, an operator may test the alarm circuit by pressing the test button.
Each controller includes:
- Power on light
- Alarm level and leak warning lights
- Audible alarm with reset button
- Push button test
- Manual - off - automatic illuminated pump mode
selector switch for each pump specified
- Motor contactor for each pump specified
- 115 volt / 60 Hz, single phase standard, other voltages available
|
Part
Number |
Control
Function |
Description |
PTC-10S |
Simplex
(1) Supply Pump |
For
operating one supply (tank fill) pump, up to a 3/4 HP single phase motor
with tank high level, low level and tank leak alarms (Requires Option #
1250d) |
PTC-10S-DR |
Same as above with tank level indication
(Requires Option # 1251) |
|
|
|
PTC-20SS |
Duplex
(2)
Supply Pump
|
For operating two supply (tank fill) pumps with automatic pump alternation,
up to a 3/4 HP single phase motor with tank high level, low level and tank
leak alarms (Requires Option # 1250d) |
PTC-20SS-DR |
Same as above with tank level indication
(Requires Option # 1251) |
|
|
|
PTC-10R |
Simplex
(1) Return Pump |
For operating one
return (tank empty) pump, up to a 3/4 HP single phase motor with tank high
level and tank leak alarms (Requires Option # 1250c) |
PTC-10R-DR |
Same as above with tank level indication
(Requires Option # 1251) |
|
|
|
PTC-20RR |
Duplex
(2)
Return Pump
|
For operating two
return (tank empty) pumps with automatic pump alternation, up to a 3/4 HP single phase motor with tank high
level with tank leak alarms (Requires Option # 1250d) |
PTC-20RR-DR |
Same as above with tank level indication
(Requires Option # 1251) |
|
|
|
PTC-20SR |
Single
Supply Pump (1)
& Single Return (1) Pump
|
For operating one supply (tank fill) and one return (tank empty) pump, up to a
3/4 HP single phase motor with high-high & high level, low level with
tank leak alarms. (Requires Option # 1250e) |
PTC-20SR-DR |
Same as above with tank level indication
(Requires Option # 1251) |
|
|
|
PTC-30SSR |
Duplex
(2) Supply Pump & Simplex (1) Return Pump |
For operating
duplex (two) supply (tank fill) pumps with automatic alternation and one
return (tank empty), up to a 3/4 HP single phase motor with tank high-high,
high, low level with tank leak alarms. (Requires Option # 1250e) |
PTC-30SSR-DR |
Same as above with tank level indication
(Requires Option # 1251) |
Our Most Popular Options
|
Option |
Description |
1250 |
c-
Three level float switch for tank high level, pump on & pump off with explosion proof junction box. (Note: to be used with PTC-10R or PTC-20RR series, specified tank size, 1” NPT tank top fitting required) |
|
d
- Four level float switch for tank high level, pump on, pump off & low level with explosion proof junction box. (Note: to be used with PTC-10S or PTC-20SS series, specified tank size, 1” NPT tank top fitting required) |
|
e
- Five level float switch for tank high-high and high level, pump on, pump off & low level with explosion proof junction box. (Note: typically used with PTC-20SR, PTC-30SSR series, specified tank size, 1” NPT tank top fitting required) |
1251 |
Continuous reading level gauge, capacitance type with explosion proof junction box (Note: tank size must be specified, 3/4” NPT tank top fitting required, shipped loose with system) |
PHILLIPS PUMP specializes in controlling, monitoring and transferring fuel........
Let us help design a system that works for you
| |
|