Double Wall Day Tanks With Pumps And Controls
|
Phillips Pump double wall (PDWT) day tanks provide a ready supply of oil
or diesel fuel for boilers, diesel generators, or other stationary, engine-driven or burner-fired
equipment. With capacities ranging from 25 to 500 gallons, Phillips Pump
day tanks may be selected
for maximum fuel capacity for placement in a minimum amount of space.
Our PWDT series of double wall day tank/pump systems has an integral higher capacity outer chamber to
protect against spills in event of leaks due to a high pressure rupture or internal damage to the
inner tank. Each day tank/pump system includes 2 GPM pump(s) as standard with
pump / level controller, a
mechanical gauge for visual level indication, a UL sized vent port, a
4" NPT inspection / emergency vent
port, 2" NPT manual fill port, 1" NPT pump fill, engine supply, engine return,
overflow, and drain ports.
All tanks are manufactured in accordance with a UL 142 label and meet NFPA 30 standards. Each Phillips
Pump day tank is constructed from 10 gauge steel, internally reinforced and seam welded to provide long lasting
life in rugged industrial and commercial environments.
Each Day Tank / Pump System Includes:
- Heavy gauge, seam welded, reinforced steel tank with heavy gauge steel channel support base with
mounting holes
- Mechanical tank gauge for visual level indication
- Factory mounted 2 GPM positive displacement gear pumps with open drip-proof motors as standard
for fuel oil supply and/or return (higher flow rates, TEFC or explosion proof motors available)
- Corrosion-resistant internal epoxy coating
- Complete array of fittings and connections (see double wall fitting schedule under storage tanks)
- Engine supply and pump ports with supplied with drop tubes
- Multi-level probe for pump on/off operation and low level or high level alarms
- 135% outer chamber standard on double wall tanks
- Day tank controller, tank top factory installed, with illuminated pump manual off automatic mode
selector switches, power on, low and high level alarm indication lights, audible alarm, press to
test and system reset push-buttons and alarm dry contact for interfacing to building
management systems
- Tank, pump and control options available
to meet the specific requirements for each application
- 115 VAC, single phase, 60 Hz, other volts and three phase systems are available
|
|
Day Tank / Pump System Combinations
|
|
PDWTS Series - Double wall day tank system with a single supply pump where the fuel
can drain by gravity back to the main storage tank (suggested specification).
|
PDWTR Series - Double wall day tank system typically used for overflow tank
situations where the fuel source is above the day tank. System comes complete
with a single return pump only (suggested specification).
|
|
PDWTSS Series - Double wall day tank system typically used in mission critical
situations where supply must be maintained. System comes complete with (2)
supply pumps with automatic pump alternation and automatic lag pump start on low
level alarm (suggested specification).
|
PDWTSR Series - Double wall typically used in day tank systems where the main storage
tank is on the same level with the day tank when a single supply pump is required
with a single return to drain tank in a high level alarm condition
(suggested specification).
|
|
PDWTRR Series - Double wall day tank system typically use for overflow tank
situations where the fuel source is above the day tank and a back up pump is
required. System comes complete with (2) return pumps, automatic return pump
alternation with automatic lag return pump start on a high level alarm
(suggested specification).
|
PDWTSSR Series - Double wall day tank system with duplex (2) supply and (1) return
pump typically used in mission critical systems when fuel supply must be maintained
and where the main storage tank is on the same level. System comes complete with
(2) supply pumps, with supply automatic pump alternation, automatic lag supply pump start
on low level alarm and a single return to drain tank in a high level alarm situation
(suggested specification).
|
|
Gallons |
Double wall tank with (1) supply pump & controls |
Double wall tank with (1) return pump & controls |
Double wall tank with duplex (2) supply pumps & controls |
Double wall tank with (1) supply & (1) return pump & controls |
Double wall tank with duplex return pumps & controls |
Double wall tank with duplex supply & (1) return pump & controls |
25 |
PDWTS-25 |
PDWTR-25 |
PDWTSS-25 |
PDWTSR-25 |
PDWTRR-25 |
PDWTSSR-25 |
50 |
PDWTS-50 |
PDWTR-50 |
PDWTSS-50 |
PDWTSR-50 |
PDWTRR-50 |
PDWTSSR-50 |
60 |
PDWTS-60 |
PDWTR-60 |
PDWTSS-60 |
PDWTSR-60 |
PDWTRR-60 |
PDWTSSR-60 |
75 |
PDWTS-75 |
PDWTR-75 |
PDWTSS-75 |
PDWTSR-75 |
PDWTRR-75 |
PDWTSSR-75 |
100 |
PDWTS-100 |
PDWTR-100 |
PDWTSS-100 |
PDWTSR-100 |
PDWTRR-100 |
PDWTSSR-100 |
150 |
PDWTS-150 |
PDWTR-150 |
PDWTSS-150 |
PDWTSR-150 |
PDWTRR-150 |
PDWTSSR-150 |
200 |
PDWTS-200 |
PDWTR-200 |
PDWTSS-200 |
PDWTSR-200 |
PDWTRR-200 |
PDWTSSR-200 |
250 |
PDWTS-250 |
PDWTR-250 |
PDWTSS-250 |
PDWTSR-250 |
PDWTRR-250 |
PDWTSSR-250 |
275 |
PDWTS-275 |
PDWTR-275 |
PDWTSS-275 |
PDWTSR-275 |
PDWTRR-275 |
PDWTSSR-275 |
325 |
PDWTS-325 |
PDWTR-325 |
PDWTSS-325 |
PDWTSR-325 |
PDWTRR-325 |
PDWTSSR-325 |
400 |
PDWTS-400 |
PDWTR-400 |
PDWTSS-400 |
PDWTSR-400 |
PDWTRR-400 |
PDWTSSR-400 |
500 |
PDWTS-500 |
PDWTR-500 |
PDWTSS-500 |
PDWTSR-500 |
PDWTRR-500 |
PDWTSSR-500 |
Note: To delete the pump from single pump systems or a pump from
dual pump systems, specify (1)
option 1002. To delete both pumps from dual pump systems specify option 1003.
|
Our Most Popular Options
|
Option |
Description |
1010 |
Auxiliary hand pump, rotary vane type, 10 GPM at 135 RPM |
1015 |
Auxiliary hand pump, piston type, 20 GPM per 100 strokes |
1025 |
Manual fuel fill cap, 2" lockable |
1040 |
Wall mounting brackets (available on double wall tanks or single wall tanks without basin) |
1050 |
Pipe stand adapters to raise tank above floor |
1055 |
Simplex fuel strainer on supply pump inlet |
1060 |
Duplex strainer with selector valve on supply pump inlet |
1063 |
Vent cap, screened, for installation at outdoor vent termination |
1064 |
Emergency vent, 4" NPT |
1065 |
Drain valve with locking handle |
1070 |
Priming tee and check valve assembly; factory assembled unit consisting of a plugged
pump priming tee, a plugged fuel line priming tee and check valve |
1080 |
Solenoid valve, normally closed to prevent loss of prime or tank flooding |
1081 |
Solenoid valve, normally open, to shut down flow for additional protection in case of a high level alarm |
1082 |
Flow control manifolds, factory assembled units consisting of: i) one normally closed solenoid valve to
direct flow for multi-tank applications and to prevent loss of prime or tank flooding, ii) one normally
open solenoid valve to shut down flow and provide additional protection in case of a high level tank
condition, and iii) two isolation valves and manual bypass tee with ball valve
|
1087 |
Manual shut off ball valves, bronze body |
1088 |
Manual shut off ball valves, fire rated |
1090 |
Foot valve, 1" NPT on engine supply drop tube to prevent loss of prime |
1092 |
Fusible link valve, lever type (includes wire coil and fuse link)
|
1093 |
Fusible link valve, arm type |
1094 |
Check valve, bronze, swing type |
1095 |
Pump internal relief valve |
1100 |
Pressure gauge, liquid filled, on pump discharge |
1101 |
Compound vacuum/pressure gauge on suction side of pump |
1103 |
Flow indictor, ball type |
1130 |
Extra engine supply or engine return pipe connections; includes drop tubes
(please specify location and quantity)
|
1132 |
Extra piping connections (please specify location and quantity) |
1135 |
Oversized piping connections |
1180 |
Weatherproof modification |
1191 |
Rupture basin leak sensor (available for double wall tanks or single wall tanks with basin) |
1197 |
Fuel in vent detection sensor |
1211 |
Sight glass with steel guard and valves |
1285 |
Single level float level probe, Buna N float with brass stem and locking rings, single
level (note: typically for high level auxiliary indication)
|
1490 |
a) 4 GPM supply or return pump with, 1/3 HP, 1725 RPM motor
|
|
b) 7 GPM supply or return pump with, 1/2 HP, 1725 RPM motor
|
|
c) 10 GPM supply or return pump with, 3/4 HP, 1725 RPM motor
|
|
d) 15 GPM supply or return pump with, 1 HP, 1725 RPM motor
|
|
e) 23 GPM supply or return pump with, 1 1/2 HP, 1725 RPM motor |
| |
|